On Demand Tankless Hot Water Systems – Navien NPE-210A

Navien NPE 210A

Ultra Condensing Efficiency

Navien’s Condensing Technology offers the high efficiency.
Money and energy savings over tank type water heaters and traditional water heaters.

Two Stainless Steel Heat Exchangers

Provides longer life expectancy as they are highly resistant to corrosion and erosion compared to copper heat exchangers.
Reduces minerals deposits.

Low NOx Emissions (≤ 20ppm)

New metal fiber burner is designed to deliver a consistent air/gas mixture improving combustion efficiency.
Result in less acid rain and less green house effect.
Comply with SCAQMD 1146.2 strict NOx emissions standard.

2” PVC, CPVC, Polyprophylene Venting Up To 60’

2” venting option allows for a flue to be pulled through the existing vent.
3โ€ vents can be used up to 150โ€™ with standard 2โ€ x 3โ€ adapters.

Utilizes Existing 1/2″ Gas Line

The negative pressure gas valve and fan with dual venturi operation allows for better adaptability to low gas pressure applications.
Makes it possible for the NPE to be installed ยฝโ€ gas lines up to 24โ€™.

Field Convertible

NPE models allow for easy convertibility from NG to LP.

Less Water Pressure Drop

Simple modular for water path minimizes water pressure drop.
Modular design for water path make maintenance easier and service can be performed easily in the field.

Intelligent Preheating Technology

Recognizes hot water usage patterns to intelligently provide hot water when needed.

Data FieldNPE-210A
Heat Capacity (Input)Natural Gas19,900-180,000 BTU/H
Propane Gas19,900-180,000 BTU/H
Energy Factor NG / LPG (DOE)0.97 / 0.97
Flow Rate (DHW)35โฐF(19โฐC) Temp Rise10.1 GPM (38 L/m)
45โฐF(25โฐC) Temp Rise7.8 GPM (30 L/m)
77โฐF(43โฐC) Temp Rise4.6 GPM (17 L/m)
Dimensions17.3″(W) x 27.4″(H) x 13.2″(D)
Weight82 lbs (37 kg)
Installation TypeIndoor or Outdoor Wall-Hung
Venting TypeForced Draft Direct Vent
IgnitionElectronic Ignition
Water Pressure15-150 PSI
Natural Gas Supply Pressure (from source)3.5″-10.5″ WC
Propane Gas Supply Pressure (from source)8″-13″ WC
Natural Gas Manifold Pressure (min to max)-0.04″ WC to -0.36″ WC
Propane Gas Manifold Pressure(min to max)-0.02″ WC to -0.66″ WC
Minimum Flow Rate0 GPM (0 L/m)
Connection SizesCold Water Inlet3/4″ NPT
Hot Water Outlet3/4″ NPT
Recirculation Inlet3/4″ NPT
Gas Inlet3/4″ NPT (Suitable for use with 1/2″ rigid gas pipe; refer to installation
manual for sizing criteria)
Power SupplyMain Supply120 V AC, 60Hz
Maximum Power Consumption200W (max 2A), 350W (max 4A) with external pump connected
MaterialsCasingCold rolled carbon steel
Heat ExchangersPrimary Heat Exchanger: Stainless Steel Secondary Heat Exchanger:
Stainless Steel
VentingExhaust2″ or 3″ PVC, CPVC, Polypropylene 2″ or 3″ Special Gas Vent Type BH (Class
II, A/B/C)
Intake2″ or 3″ PVC, CPVC, Polypropylene 2″ or 3″ Special Gas Vent Type BH (Class
II, A/B/C)
Vent Clearances0″ to Combustibles
Safety DevicesAPS, Ignition Operation Detector, Water Temperature High Limit Switch,
Exhaust Temperature High Limit Sensor, Power Surge Fuse
Scroll to Top